  powerline ac/dc-converter with 3 year warranty rac10-c/277 10 watt single / dual output very compact low ac/dc power supply high efficiency single & dual output options continuous short circuit protection isolated output 3.75kvac/1 min en55022 class b compliant high operating temperature low standby power consumption features regulated converters selection guide part input output output efficiency max. number range voltage current (typ.) capacitive load (vac) (vdc) (ma) (%) (f) (1+2) rac10-3.3sc/277 80-305 3.3 2500 75 50000 rac10-05sc/277 80-305 5 2000 78 36000 rac10-12sc/277 80-305 12 840 80 8600 rac10-15sc/277 80-305 15 670 78 6000 rac10-24sc/277 80-305 24 420 80 2700 rac10-05dc/277 80-305 5 1000 77 21000 rac10-12dc/277 80-305 12 420 79 3700 rac10-15dc/277 80-305 15 340 79 2900 input voltage range (with derating) 80-305vac or 113-430vdc rated power 10 watts input frequency range (for ac input) 47-63hz input current (full load) 115vac 250ma typ. 230vac 160ma typ. no load power consumption 230vac 300mw max. inrush current (cold start-up) 115vac 15a max. 230vac 30a max. leakage current 250vac/50hz 0.25ma max. external fuse recommended 1.5a slow blow type output voltage accuracy 3.3v 3% typ. all others 2% typ. line voltage regulation (low line, high line at full load) 0.3% typ. load voltage regulation 3.3v, 5v -1.5% typ. (0 -100% load) 12v 1% typ. all others 0.5% typ. minimum load 0% output ripple and noise 3.3v / 5v 50mvp-p typ. (with 0.1f across outputs 12v / 15v / 24v 125mvp-p typ. @20mhz bandwidth) 5 200mvp-p typ. 12 125mvp-p typ. 15 200mvp-p typ. operating frequency 100khz hold-up time 230vac/50hz 60ms min. isolation voltage (input to output) 3.75kvac / 1minute short circuit protection hiccup, automatic restart continued on next page specifications (measured at ta 25c, full load after warm-up) + 3"  # " '       $ " ' # $   "  en60950-1 certified ul60950-1 certified ce marked e224736 rohs 2011/65/eu 6/6 refer to application notes derating-graph (ambient temperature) www.recom-power.com pa-39 rev: 1/2015
rac10-c/277 powerline ac/dc-converter characteristics (measured @ 115/230vac, 50/60hz after warm up)    $     $    !" #$$%
%&" <-;)" <-;)" <-;)" <-";)" <-"';)"    $     $    !" #$$%
%&" <-;)" <-;)" <-";)" rac10-xxsc/277 rac10-xxdc/277 specifications (measured at ta 25c, full load after warm-up) output overvoltage protection latch off over voltage category ovc ii overcurrent protection automatic recovery operating temperature range (free air convection, with derating) -20c to +70c storage temperature range -40c to +7 5c humidity 95% rh max. case material epoxy with fibreglass (ul94v-0) dimension (l x w x h) 52.4 x 27.4 x 23.5mm package weight 62g5g certifications ul general safety report: e224736-a20 ul60950-1, 2nd edition iec/en general safety report: spclvd1210109 en60950-1, 2nd edition emc report: t121026n02-e en 55022 class b report: t121026n02-e en 55024 mtbf (+25c) using mil-hdbk-217f 320 x 10 3 hours (+70c) using mil-hdbk-217f 120 x 103 hours  " *   * " ' # $   * * "  "'  "  /    " *   * " ' # $   * * " 3 3 3"  /   rac10-xxs_dc /277 series input voltage vs load    ! "    $ ;  6 -  6     # #   $  notes: note1: measured @ 230vac / 50hz / ta=25c with constant resistant mode at full load. note2: if used @ 115vac / 60hz with full load, max. capacitive load is less, please contace recom for detailed information. pa-40 www.recom-power.com rev: 1/2015
rac10/277 powerline ac/dc-converter %$ #% % % $% % % %   % % #% # $ % %$ %$ % & '%(%  % 

  
    
  xx.x 0.5 mm xx.xx 0.25 mm pin connections- pin # single out 1 vac in (n) 2 vac in (l) 3 -vdc out 4 +vdc out rac10-xxsc/277 application notes rac10-xxs_dc /277 series -   - . /
! /
 9
 "-;8&28& 6 
9) =
< > -  /
! - ./
 
9) 
9) 9
 "-;8&28& 6 /
! : /
 -/ -/ -/ /0- ;.= 4 9
 "-8&28& 6 . -   - . /
! : /
 - - "- " - standard application circuit 1. recommended external input fuse 1.5a / slow blow type. 2. do not use scope ground lead to measure the output ripple & noise. standard package style and pinning www.recom-power.com pa-41 rev: 1/2015
%$ #% % % $% % % %   % % #% # $ % %$ %$ % & '%(% % %   % 

  
    
  xx.x 0.5 mm xx.xx 0.25 mm pin connections- pin # single out 1 vac in (n) 2 vac in (l) 3 -vdc out 4 com 5 +vdc out rac10-xxdc/277 rac10/277 powerline ac/dc-converter rac10-xxs_dc /277 series standard package style and pinning the product information and specifications are subject to change without prior notice. recom products are not authorized for us e in safety-critical applications (such as life support) without recoms explicit written consent. a safety-critical application is defined as an applica tion where a failure of a recom product may reasonably b e expected to endanger or cause loss of life, inflict bodily harm or damage property. the buyer shall indemnify and hold harmless recom, its affiliated companies and its representatives against any damage claims in connecti on with the unauthorized use of recom products in such safety-critical applications. pa-42 www.recom-power.com rev: 1/2015


▲Up To Search▲   

 
Price & Availability of RAC10-05DC277

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X